How to Measure a Gym Cable for Replacement or OEM Orders
To order a replacement or custom gym cable, we need five details: the finished length, the coated outside diameter, the steel-core diameter (if known), both end fittings and the coating type. Clear photos of both ends next to a ruler let our engineers check anything that is missing, usually without needing the original cable.
What you need to measure
| Detail | How to get it | Tool | Example |
|---|---|---|---|
| Finished length | Overall length from the outer end of one end fitting to the outer end of the other, with the cable laid straight and not under load | Steel tape measure | 1,850 mm |
| Coated outside diameter (OD) | At two or three unworn points along the coated section | Digital caliper | 5.6 mm |
| Steel-core diameter | From the original specification or a stripped end, if available. If not, skip it; we confirm it during technical review | Digital caliper | 4.0 mm |
| End fittings (both ends) | Identify the type, then record thread size, shank or ball diameter and eyelet hole diameter | Caliper, thread gauge | M10 threaded plug |
| Coating and colour | PA11 nylon, TPU, PU or PVC if known; any printing on the cable | Photo | Black PA11 |
| Machine model and quantity | From the nameplate or manual | None | Cable crossover, 20 pcs |
Step-by-step: measuring a gym cable
-
Remove the cable safely
Unload the weight stack and follow the equipment manufacturer’s maintenance instructions before removing the cable. Lay it straight on a flat surface.
Safety: never remove or loosen a cable while the weight stack is loaded or raised. -
Measure the finished length
With the cable straight and not under tension, measure the overall length from the outer end of one end fitting to the outer end of the other, as shown in the diagram. Record the result in millimetres and measure twice.
-
Measure the coated outside diameter
Use a caliper at two or three points along the coated section. Avoid worn, flattened or damaged areas, because they read smaller than the true diameter. Record the OD in millimetres.
-
Identify and measure both end fittings
Fittings can differ at each end, so check both. If you know the YR code (for example YR-1602-A), just send it and you can skip most dimensions; the full list is on our fittings page. Otherwise match each fitting to a type below and record its key dimensions.
Fitting type Series Record Shank ball joint YR-1602 Head diameter (8.5, 10, 11.6 or 14 mm), shank dimensions, overall length and inner hole diameter; do not confuse the cable-entry hole with the head diameter Metal eyelet joint YR-1603, YR-1604, YR-1618 Eye inner diameter, overall length, inner hole diameter Screw bolt / thread plug YR-1610 (M8, M10), YR-1611 (M12, M14, M16) Thread size, thread length, head or hex size Clevis strap fork YR-1617 Fork opening width, pin hole diameter, overall length Ball stopper / cable stopper / lock sleeve connector YR-1606, YR-1605 Ball or body diameter, overall length, how it is fixed (screw or crimp) Aluminum sleeve, cylinder, T-shape joint YR-1630, YR-1616, YR-1613 Outer diameter, inner hole, overall length Complete cable sets can combine any two of these ends (our Gym Cable Set types 1–28), so tell us the type or code for each end separately.
-
Note the coating and colour
Record the coating material if you know it (PA11 nylon, TPU, PU or PVC), the colour, and any text or markings printed on the cable. If you are unsure, say so and send a photo.
-
Photograph both ends and send
Place each end beside a ruler or tape measure so the scale is visible. Take one photo from the side and one from the front or top of each fitting, then send them with your measurements, machine model and quantity.
How we define finished length
The method illustrated in this guide is overall length: measure from the outermost end of fitting 1 to the outermost end of fitting 2, including both fittings. Depending on the fitting, this may be the outer tip of a ball, the end of a threaded stud, the outer edge of an eyelet or the end face of a sleeve. If your original drawing uses bearing-point length, send the drawing or a photo with both reference points marked so we can help check the corresponding overall length. Confirm the measurement reference and final dimensions on the order drawing before production.
Photos that help us quote faster
- Both ends in focus, each beside a ruler or tape measure
- A side view and a front or top view of each fitting
- The full cable laid straight, with the tape measure visible along its length
- Any printing, label or colour band on the cable
- The machine nameplate or model, if possible
Common measuring mistakes
- Measuring a coiled or stretched cable. Lay it straight and relaxed.
- Mixing up diameters. Coated OD and steel-core diameter are different numbers. Tell us which one you measured.
- Measuring a worn section. Wear and flattening make the OD read low.
- Measuring only one end fitting. The two ends are often different.
- Photos without a scale. A ruler in the frame removes most guesswork.
Copy and send this template
Paste this into an email or WhatsApp message and fill in what you know. Leave blanks for anything you are unsure about.
Machine model: ____ Finished length (mm): ____ Coated OD (mm): ____ Steel-core diameter (mm, if known): ____ End fitting 1 (YR code or type / size): ____ End fitting 2 (YR code or type / size): ____ Coating / colour: ____ Quantity: ____ Photos of both ends attached: yes / no
OEM buyers can send a technical drawing instead, with end-to-end dimensions, tolerances, coating, fittings and required quantity.
Frequently asked questions
Do I need to send the original cable?
No. For standard colours, clear photos and accurate measurements, or a technical drawing, are normally sufficient. A physical sample is only needed when an exact custom coating colour must be matched.
What if I cannot remove the cable from the machine?
Send photos of both ends, the machine model and any measurements you can take safely. Our engineers will tell you which dimensions are still missing.
What if I do not know the steel-core diameter?
Send the coated outside diameter and clear photos. The steel-core diameter can be confirmed during technical review.
What if my end fitting is not a standard type?
Send a drawing or clear photos from several angles with a scale. We stock more than 60 standard fittings and can make custom fittings from drawings.
How long does the technical review take?
We review your information and confirm any missing dimensions or drawing details before we quote.
Send us your measurements
Share your measurements and photos and we will confirm the specification before quoting. Production begins only after you approve it.